Cumulus Networks provides this document as a suggested procedure for qualifying a transceiver module or cable that doe not appear on the Cumulus Linux Hardware Compatibility List (HCL) as a recommended pluggable. Cumulus Networks will not actively prevent any non-recommended pluggable from functioning and does not restrict the use of self-qualified pluggables. However, Cumulus Networks recommends customers use the pluggables listed on the HCL. Customers who wish to use a non-recommended pluggable can follow the suggested procedure outlined in this document. For concerns about pluggables that are not listed, please contact your Cumulus Networks sales team.
Example Connections
This procedure is valid for qualifying all types of transceivers and cables in a device undergoing testing. Customers can choose the same types or a combination of different transceivers for this test.
The following diagram illustrates an example where the top and bottom ports are connected with a cable as a loopback. The example includes cabling and configuration for the testing of both 40G QSFP and 10/1G SFP. Cumulus Networks recommends that different speed components be tested independently. The example includes both in order to simplify the presentation.
TG-1/TG-2 are either networking traffic generators (IXIA/Spirent or equivalent) or two servers with a Linux OS installed and iperf3 free traffic generator tool or an equivalent.
Cumulus Linux Configuration
Modify the /etc/network/interfaces
file with the following bridge configuration:
auto trg_1 iface trg_1 inet manual bridge_ageing 150 bridge_stp off bridge_ports swp41 swp52 up ip link set trg_1 up auto trg_2 iface trg_2 inet manual bridge_ageing 150 bridge_stp off bridge_ports swp42 swp43 up ip link set trg_2 up auto l_1 iface l_1 inet manual bridge_ageing 150 bridge_stp off bridge_ports swp51 swp50 up ip link set l_1 up auto l_2 iface l_2 inet manual bridge_ageing 150 bridge_stp off bridge_ports swp49 swp48 up ip link set l_2 up auto l_3 iface l_3 inet manual bridge_ageing 150 bridge_stp off bridge_ports swp47 swp46 up ip link set l_3 up auto l_4 iface l_4 inet manual bridge_ageing 150 bridge_stp off bridge_ports swp45 swp44 up ip link set l_4 up
The following bridge configuration is expected after you reboot the switch being tested.
~$ sudo brctl show bridge name bridge id STP enabled interfaces l_1 8000.443839002076 no swp50 swp51 l_2 8000.443839002071 no swp48 swp49 l_3 8000.44383900206f no swp46 swp47 L_4 8000.44383900206e no swp44 swp45 trg_1 8000.44383900206c no swp43 swp52 trg_2 8000.44383900206d no swp44 swp45
Verifying Link Status
Run the following Cumulus Linux command to verify that all loopback links are up:
~$ sudo ethtool swp50 Settings for swp50: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full 40000baseT/Full Supported pause frame use: Symmetric Receive-only Supports auto-negotiation: Yes Advertised link modes: 1000baseT/Full 10000baseT/Full 40000baseT/Full Advertised pause frame use: Symmetric Advertised auto-negotiation: No Speed: 40000Mb/s Duplex: Full Port: FIBRE PHYAD: 0 Transceiver: external Auto-negotiation: off Current message level: 0x00000000 (0) Link detected: yes
Activating Data Traffic from Linux Servers
Configure the server interfaces connected to traffic ingress/egress ports to set IPv4 addresses in the same IP subnet. For example:
TG1$ sudo ifconfig eth1 101.0.1.1/24 up TG2$ sudo ifconfig eth1 101.0.1.2/24 up
You can try ping
or ping –f
(flood) between these interfaces.
For generating iperf
traffic, use options like the following (for example):
TG1$ sudo iperf -s -B 101.0.1.1 -p 9000 TG2$ sudo iperf -c 101.0.1.1 -i 3 -t 600 -p 9000 –d
Where:
- -B is bound to an interface
- -p is TCP port number
- -c is iperf destination
- -i is print to screen interval
- -t is duration of the test in seconds
- -d is bidirectional traffic
Confirm that ping
and iperf
traffic reach the destination and the bandwidth matches the expected rate (subject to the transceiver's supported speed and the server CPU). Connect two servers back-to-back first to capture baseline server performance characteristics.
Transceivers Module Information (EEPROM & DOM)
Use the following Cumulus Linux command to check each transceiver's EEPROM and Digital Optical Monitoring (DOM) information:
~$ sudo ethtool –m swp<id>
Cumulus Linux-based Error Counters Check
The following commands indicate error and drop counters occurred during and after the test:
~$ sudo ethtool -S swp<id> | grep -i error HwIfInDot3LengthErrors: 0 HwIfInErrors: 0 SoftInErrors: 0 SoftInFrameErrors: 0 HwIfOutErrors: 0 SoftOutErrors: 0
PASS/FAIL Criteria
The following checklist and test plan constitutes successful results.
Test/Check |
Expected Result |
Comment |
$ ping –f <dest IP> |
% packets drop |
Source and destination IP of TG1 & TG2 |
$ iperf TCP stream |
Bidirectional traffic with Cumulus Linux snake test matches transfer rate of two traffic generators’ endpoints when connected back-to-back. |
|
$ ethtool -S swp<id> | grep -i error |
All error counters return null. |
To detects drops or errors, collect output from |
$ ethtool swp<id> |
Link up |
|
$ ethtool -m swp<id> |
Returns EEPROM information, such as vendor and equipment type. |
DOM information is optional for successful self-qualification of transceivers. In some cases ODM vendors elect to restrict information programmed for DOM. |
$ sudo systemctl reset-failed switchd.service |
After the |
This test confirms that a |
Reboot the switch and repeat same tests and checkpoints again. |
All checks/tests iterations are successful. |
During some transceivers' qualification cycle, Cumulus Networks observed occasionally that marginal and disqualified transceivers exhibited failures with 10-25% failure rates across switch reboots. |