Comparing Common Layer 2 Configurations to Arista and Cisco

Follow

The configuration of layer 2 networking in Cumulus Linux (or any Linux distribution for that matter) is different from the incumbent network operating systems like Cisco's NX-OS or Arista's EOS. This article details some of the syntax differences using common layer 2 examples.

{{table_of_contents}}

Configuring Trunks

Configuring trunks with two VLANs on ports 1 and 2:

Cumulus Linux Cisco NX-OS Arista EOS
auto bridge
iface bridge
  bridge-vlan-aware yes
  bridge-ports glob swp1-2
  bridge-vids 100 200
    
vlan 100,200

interface ethernet 1/1
    switchport mode trunk

interface ethernet 1/2
    switchport mode trunk  

!
vlan 100,200 !
interface Ethernet1 switchport mode trunk !
interface Ethernet2 switchport mode trunk

Pruning a Trunk

Pruning VLAN 100 from the trunk on port 1:

Cumulus Linux Cisco NX-OS Arista EOS
auto bridge
iface bridge
  bridge-vlan-aware yes
  bridge-ports glob swp1-2
  bridge-vids 100 200
auto swp1 iface swp1 bridge-vids 200
vlan 100,200

interface ethernet 1/1
    switchport mode trunk
    switchport trunk allowed vlan 200

interface ethernet 1/2
    switchport mode trunk
!
vlan 100,200 !
interface Ethernet1 switchport mode trunk !
interface Ethernet2 switchport mode trunk switchport trunk allowed vlan 200

Configuring Access Ports

Configuring two VLANs in access mode: port 1 VLAN 100 and port 2 VLAN 200:

Cumulus Linux Cisco NX-OS Arista EOS
auto bridge
iface bridge
  bridge-vlan-aware yes
  bridge-ports glob swp1-2
  bridge-vids 100 200
auto swp1 iface swp1 bridge-access 100
auto swp2 iface swp2 bridge-access 200
vlan 100,200

interface ethernet 1/1
    switchport mode access
    switchport access vlan 100

interface ethernet 1/2
    switchport mode access
    switchport access vlan 200

!
vlan 100,200 !
interface Ethernet1 switchport access vlan 100 !
interface Ethernet2 switchport access vlan 200

Changing the Native (Untagged) VLAN for a Single Trunk

Setting the native VLAN to 100 on port 1 and 200 on port 2 when both ports are trunks allowing VLAN 1-200:

Cumulus Linux Cisco NX-OS Arista EOS
auto bridge
iface bridge
  bridge-vlan-aware yes
  bridge-ports glob swp1-2
bridge-vids 1-200
auto swp1
iface swp1
  bridge-pvid 100
auto swp2 iface swp2 bridge-pvid 200
vlan 1-200

interface ethernet 1/1-2
    switchport mode trunk
    switchport trunk allowed vlan 1-200

interface ethernet 1/1
    switchport trunk native vlan 100

interface ethernet 1/2
    switchport trunk native vlan 200

!
vlan 1-200 !
interface Ethernet1 switchport mode trunk switchport trunk native vlan 100 !
interface Ethernet2
switchport mode trunk switchport trunk native vlan 200

See Also

Have more questions? Submit a request

Comments