Filesystem Timeouts and Read-only Filesystem on Hardware Using 3IE3/3IE4/3ME3 Solid State Disks

Follow

Executive Summary

Some SSD (solid-state disk or flash) drive models commonly used in network switches require the use of the TRIM command to function properly. By default, Cumulus Linux, like most other Linux distributions, does not enable TRIM. This command enables the operating system to keep the firmware up to date on empty areas of the drive to ensure that writes work correctly. Over time, without this notification, when extensive logging or debugging to the SSD is enabled, the firmware may take longer to perform write operations, which can in turn cause driver timeouts. These disk errors may eventually lead to the filesystem being mounted as read-only.

For customers running versions 3.0.0 through 3.7.3, Cumulus Networks is distributing a package to address this issue. Since these SSD drives are widespread in networking hardware, all customers using 3IE3, 3IE4 or 3ME3 SSDs should install this package. Customers without the affected SSDs will see no behavioral change. Installing the package should have no adverse effects. This functionality will be handled automatically by Cumulus Linux 3.7.4 and later.

Issue Description

Recently, two SSD models — 3IE and 3ME — that were commonly used by manufacturers in embedded devices such as network switches were moved to End-of-Life/End-of-Sale status by the SSD manufacturer Innodisk. These models were replaced by the 3IE3, 3IE4 and 3ME3 SSDs. Although the 3IE3, 3IE4 and 3ME3 drives were thought by Innodisk to be "drop-in replacements" for the previous 3IE and 3ME drives, these drives require the ATA TRIM command to function properly, while the 3IE and 3ME drives did not.

Cumulus Linux, like most other Linux distributions, does not enable TRIM by default.

Using the TRIM command, the operating system can notify the SSD firmware which logical block addresses (LBAs) are free from the filesystem perspective so that the SSD controller can change the TRIMmed pages that map to these LBAs from VALID to INVALID.

When the SSD firmware detects that there are not enough FREE blocks on the SSD, the garbage collection feature on the SSD firmware converts INVALID pages to FREE blocks. Only pages that are marked as INVALID can be converted to FREE blocks.

On the 3IE3, 3IE4 and 3ME3 drives, with some firmware versions, the TRIM option is the only mechanism by which the operating system can notify the SSD firmware which LBAs are free. Without the TRIM command enabled on these drives, over time nearly every FREE block on the SSD will be filled with data and marked as VALID. This exhaustion of FREE blocks can cause the SSD firmware to shuffle data around the SSD to create a new FREE block for new data to be written. This is similar to defragmenting non-SSD drives. This process is time consuming and can result in disk driver timeouts in the operating system during disk writes, which can in turn cause the filesystem to be mounted as read-only.

Environment

Network Operating System

Cumulus Linux versions 3.0.0 through 3.7.3.

Hardware

Cumulus Networks supports a large number of devices with 3IE3/3IE4/3ME3 SSDs.

To determine if you have the affected hardware, run: 

cumulus@switch:~$ ls /dev/disk/by-id | egrep '3ME3|3IE3|3IE4'

If the command has no output, then you aren't affected.

Resolution

Cumulus Networks is distributing a package named cumulus-trim that is compatible with Cumulus Linux versions 3.0.0 through 3.7.3 that mitigates the potential for customer devices to encounter this failure. Cumulus Linux 3.7.4 and later releases will detect drives that require TRIM and enable the discard option when creating the /etc/fstab file during the installation of the network operating system. The /etc/fstab file will also be updated to enable the discard option when running apt-get upgrade to upgrade to Cumulus Linux 3.7.4 or later.

Installation

To install the cumulus-trim package, run the following commands. Once installed, the package automatically executes and performs actions if it detects the affected drives.

cumulus@switch:~$ sudo -E apt-get update
cumulus@switch:~$ sudo -E apt-get install cumulus-trim

Operation

The cumulus-trim package does the following if it detects a drive that requires the TRIM command:

  • Executes the /sbin/fstrim command during the package installation to instruct the SSD firmware to mark pages associated with free LBAs as INVALID, making them eligible to be converted to FREE blocks.
  • Creates a cron job to execute /sbin/fstrim every 6 hours to notify the SSD firmware of free LBAs, allowing the SSD to mark the associated physical block addresses (PBAs) as INVALID and eligible to be converted to FREE blocks.
  • Modifies the /etc/fstab to enable the discard option on the SSD mount points. The discard option tells the filesystem layer of the operating system to send TRIM commands to the SSD firmware whenever a range of filesystem blocks is freed by the filesystem, such as when a file is deleted or partially overwritten with a smaller file.
  • The next time the switch is booted after the package is installed, the discard option is detected as enabled, /sbin/fstrim is run one last time, and the cron job is then removed, as it is no longer necessary.
Have more questions? Submit a request

Comments

  • Avatar
    drew mouw

    certain ACCTON / Edgecore switches contain USB storage which is not able to perform the TRIM function and will eventually put the files system in read-only.

    the above command does not account for the USB drive, must run the following command to verify USB storage:

    smartctl -i /dev/sda

    output of affected systems:

    /dev/sda: Unknown USB bridge [0x13fe:0x5200 (0x100)]

  • Avatar
    Pete Bratach

    Thanks for letting us know, Drew. We didn't find this to be the case in our testing, where the Accton switches completely ignore both the fstrim command and discard in the mount options. This was our experience with the cumulus-trim package and btrfs.

    Can you let us know which model or models you've had to do this with? Thanks!

  • Avatar
    Rob Stevens

    How do you recover if your filesystem has already been marked read-only?

  • Avatar
    Pete Bratach

    Hi Rob, the first thing to do is to try rebooting (at a time when it's OK if the switch doesn't come up to a usable state) into single user mode[1], and then, if it's a drive that supports and requires TRIM, running `fstrim -v /`. If you can't even boot to single user mode (rescue mode), then the drive is probably shot, and it's not TRIM related.

    1. https://docs.cumulusnetworks.com/cumulus-linux/Monitoring-and-Troubleshooting/Single-User-Mode-Password-Recovery/

  • Avatar
    Pete Bratach

    Moreover, you can't assume that a read-only state is due to the TRIM behavior. Cumulus support often sees read-only states happen when the drive is hosed for other reasons — the drive is worn or faulty and so forth.

    In theory you can try to remount the filesystem as read-write using ​`sudo mount -o remount,rw `, but if the drive is hosed then all you can really do is power cycle and hope it comes back. Ideally you'll be able to get things like syslog and kernel logs before power cycling, so you can check if there's anything logged that might give an indication as to what caused the read-only remount.