What's New in Cumulus NetQ 2.3

Cumulus NetQ 2.3 improves your operational efficiency by providing LDAP integration to work in conjunction with your enterprise management strategies and network state and configuration comparisons to reduce network downtime from unexpected behaviors due to configuration changes or upgrades.

Cumulus NetQ 2.3.0 includes the following new features and improvements:

For on-premises and cloud solutions

  • Graphical User Interface (UI)
    • Added lifecycle management feature that enables a user to compare snapshots of the live network state and configuration before and after changes are made
    • Added disk utilization to large Switches card
    • Added interface statistics and utilization to large Switches card
    • Added validation events
    • Changed references of CLAG to MLAG
  • Integrations
    • Added optional integration with open source Grafana analytics and monitoring tool
  • Command Line Interface (CLI)
    • Added netq show platform command to view NetQ software version running on device
    • Added netq show interface-utils command to view interface statistics, utilization, and port speed
    • Added netq check cl-version to validate the Cumulus Linux version running on all devices

For cloud solution only

  • Modified secure access process to use symmetric keys instead of asymmetric keys

For on-premises solution only

  • Added role-based access control (RBAC) that can be integrated with your LDAP server

Licensing

Cumulus NetQ 2.3 is available on a subscription basis as part of your support contract. For details, refer to the Cumulus NetQ Versioning and Support Policy or the Cumulus NetQ Cloud Versioning and Support Policy.

Install or Upgrade to Version 2.3

Whether you are installing Cumulus NetQ 2.3 for the first time or upgrading from an earlier version, follow the steps in the Cumulus NetQ Deployment Guide.

Documentation

The Cumulus NetQ user documentation is available online at docs.cumulusnetworks.com. You are able to provide feedback with corrections and suggestions there. This documentation is updated at every release, and periodically with corrections. Note that an updated UI User Guide may not be available for up to five days after a release. All other documents are generally available at the time of a release.

Issues Fixed in Cumulus NetQ 2.3.0

The following is a list of issues fixed in Cumulus NetQ 2.3.0 from earlier versions of Cumulus NetQ.

Release Note ID Summary Description

RN1533 (NETQ-3327)
NetQ GUI: Default BGP Validation Result card not displaying failures

When failures are present in a BGP validation, the medium and large BGP Validation Result cards do not display the failures. Additionally, the full-screen card does not open. The failures are properly counted on the small card.

This issue is fixed in Cumulus NetQ 2.3.0.


RN1534 (NETQ-3369)
NetQ CLI and GUI: Requests to view CL Support events not returning results

When running the netq show events type clsupport command or viewing CL Support alarms on the large Events| Alarms card, no data is provided.

This issue is fixed in Cumulus NetQ 2.3.0.


RN1535 (NETQ-3356)
NetQ CLI: False warnings being generated for NTP service

When running the netq show events, netq check ntp, or netq show ntp commands, false warning messages are being generated for the NTP service.

This issue is fixed in Cumulus NetQ 2.3.0.

 

Known Issues in Cumulus NetQ 2.3.0

The following known issues affect the current release.

Release Note ID Summary Description

RN-1378 (NETQ-2135)
NetQ GUI: Default BGP and CLAG Validation results do not display rotten node count

Default BGP and CLAG validation requests that produce results with rotten nodes do not display the count of these nodes on the full screen On-Demand Validation Results cards.

This is a known issue that is currently being investigated.


RN-1429 (NETQ-2601)
NetQ GUI: The Configuration File Evolution tab on the large Network Services CLAG Session card shows changes to FRRouting config

The Configuration File Evolution tab on the large Network Services CLAG Session card shows changes to the FRRouting configuration file, rather than the CLAG configuration file.

This is a known issue that is currently being investigated.


RN-1430 (NETQ-2567)
NetQ GUI: Warnings and failures on the medium Scheduled Trace Result card always show 100% when the past 24 hour timeframe is selected

When the past 24 hour time period is selected on the medium Scheduled Trace Result card, the heat maps for both warnings and failures are incorrectly displaying a saturation value of 100%. The total of the two values should equal 100%. Other time periods display correctly.

This is a known issue that is currently being investigated.


RN-1507 (NETQ-3092)
NetQ GUI: Count of OSPF alarms is not incrementing on the OSPF Network Services cards

When an OSPF alarm occurs, it is not reflected in the total alarms count on the Network Services | All OSPF Sessions cards.

This is a known issue that is currently being investigated.


RN-1508 (NETQ-3187)
NetQ GUI:Time zone disappears when user opens NetQ Management

When a user viewing the Cumulus Workbench opens the NetQ Management screen, the time zone shown in the application header no longer appears. Refreshing the browser window may resolve the issue.

This is a known issue that is currently being investigated.


RN-1528 (NETQ-2748, NETQ-3339)
NetQ GUI: Alarm and Info event information is not displayed in charts on large BGP, EVPN and OSPF Single Session cards

On large BGP, EVPN and OSPF Single Session cards, the alarm and info event data is not displayed in the respective charts.

This is a known issue that is currently being investigated.


RN-1529 (NETQ-2576)
NetQ GUI: Medium Devices | Switches card displays incorrect data

Medium Devices | Switches cards should display the distribution of overall health score for network services, interfaces, system and trace, but instead shows network-wide information.

This is a known issue that is currently being investigated.


RN-1530 (NETQ-3355)
NetQ GUI: Starting time for a scheduled trace displays incorrectly on full-screen Trace Request card

When a user creates a scheduled trace and saves it in their local time, the time is incorrectly displayed on the full-screen Trace Request card. It is correctly displayed on the large Trace Request card and through the CLI.

This is a known issue that is currently being investigated.


RN-1531 (NETQ-3255)
NetQ GUI: Configuration tab on large Scheduled Trace Result card missing data

Trace configuration information is not captured until the trace has been run at least once, leaving the large Trace Result card blank. The schedule information remains missing even after the trace has been run.

This is a known issue that is currently being investigated.


RN-1532 (NETQ-3037)
NetQ GUI: Event count is always zero on large On-demand Validation Result card for sensors

While the number of sensor-related events is one or more, the event count in the table on the large On-demand Validation Result table always displays zero. The netq show events type sensors command shows the correct information.

This is a known issue that is currently being investigated.


RN-1561 (NETQ-3618)
NetQ GUI: Snapshot creation does not complete 

When creating a network snapshot, the process does not complete. While most of the tasks do complete, the OSPF task fails and the Route task does not finish, causing the snapshot process to neither fail nor succeed.

This is a known issue that is currently being investigated.


RN-1562 (NETQ-3534)
NetQ GUI: Charts do not report peak usage on large Switch card Utilization tab

The large Switch card Utilization tab showing switch performance does not reflect peak usage for CPU, disk and memory utilization. The performance data is averaged out over a one hour period.

This is a known issue that is currently being investigated.


RN-1563 (NETQ-3461)
NetQ CLI: On Edgecore AS7816-64X switches, netq show sensors fan reports minimum RPM as -1, whereas smonctl reports it as 0 RPM

When you run netq show sensors fan on an Edgecore AS7816-64X switch, NetQ reports the minimum RPM as -1, indicating no data was successfully retrieved. However, when you run smonctl on the same switch, it reports the minimum RPM as 0.

This is a known issue that is currently being investigated.


RN-1564 (NETQ-3453)
NetQ GUI: The medium Trace Request card incorrectly displays destination MAC address option

The medium-sized Trace Request card can only be used to create a layer 3 trace request, not a layer 2 request. As such the destination address must be an IP address. The label incorrectly indicates that a MAC address can be specified.

This is a known issue that is currently being investigated.


RN-1565 (NETQ-3612)
Cannot restore backups

The provided backuprestore script cannot restore the NetQ data from the backup image. There is no workaround for this issue at this time.

This is a known issue that is currently being investigated.